09-24-2021-1002 - Fluorescence spectroscopy (also known as fluorimetry or spectrofluorometry)

 Fluorescence spectroscopy (also known as fluorimetry or spectrofluorometry) is a type of electromagnetic spectroscopy that analyzes fluorescence from a sample. It involves using a beam of light, usually ultraviolet light, that excites the electrons in molecules of certain compounds and causes them to emit light; typically, but not necessarily, visible light. A complementary technique is absorption spectroscopy. In the special case of single molecule fluorescence spectroscopy, intensity fluctuations from the emitted light are measured from either single fluorophores, or pairs of fluorophores.

Devices that measure fluorescence are called fluorometers.

Theory[edit]

Molecules have various states referred to as energy levels. Fluorescence spectroscopy is primarily concerned with electronic and vibrational states. Generally, the species being examined has a ground electronic state (a low energy state) of interest, and an excited electronic state of higher energy. Within each of these electronic states there are various vibrational states.[1]

In fluorescence, the species is first excited, by absorbing a photon, from its ground electronic state to one of the various vibrational states in the excited electronic state. Collisions with other molecules cause the excited molecule to lose vibrational energy until it reaches the lowest vibrational state from the excited electronic state. This process is often visualized with a Jablonski diagram.[1]

The molecule then drops down to one of the various vibrational levels of the ground electronic state again, emitting a photon in the process.[1] As molecules may drop down into any of several vibrational levels in the ground state, the emitted photons will have different energies, and thus frequencies. Therefore, by analysing the different frequencies of light emitted in fluorescent spectroscopy, along with their relative intensities, the structure of the different vibrational levels can be determined.

For atomic species, the process is similar; however, since atomic species do not have vibrational energy levels, the emitted photons are often at the same wavelength as the incident radiation. This process of re-emitting the absorbed photon is "resonance fluorescence" and while it is characteristic of atomic fluorescence, is seen in molecular fluorescence as well.[2]

In a typical fluorescence (emission) measurement, the excitation wavelength is fixed and the detection wavelength varies, while in a fluorescence excitation measurement the detection wavelength is fixed and the excitation wavelength is varied across a region of interest. An emission map is measured by recording the emission spectra resulting from a range of excitation wavelengths and combining them all together. This is a three dimensional surface data set: emission intensity as a function of excitation and emission wavelengths, and is typically depicted as a contour map.

Instrumentation[edit]

Two general types of instruments exist: filter fluorometers that use filters to isolate the incident light and fluorescent light and spectrofluorometers that use a diffraction grating monochromators to isolate the incident light and fluorescent light.

Both types use the following scheme: the light from an excitation source passes through a filter or monochromator, and strikes the sample. A proportion of the incident light is absorbed by the sample, and some of the molecules in the sample fluoresce. The fluorescent light is emitted in all directions. Some of this fluorescent light passes through a second filter or monochromator and reaches a detector, which is usually placed at 90° to the incident light beam to minimize the risk of transmitted or reflected incident light reaching the detector.

A simplistic design of the components of a fluorimeter

Various light sources may be used as excitation sources, including lasers, LED, and lamps; xenon arcs and mercury-vapor lamps in particular. A laser only emits light of high irradiance at a very narrow wavelength interval, typically under 0.01 nm, which makes an excitation monochromator or filter unnecessary. The disadvantage of this method is that the wavelength of a laser cannot be changed by much. A mercury vapor lamp is a line lamp, meaning it emits light near peak wavelengths. By contrast, a xenon arc has a continuous emission spectrum with nearly constant intensity in the range from 300-800 nm and a sufficient irradiance for measurements down to just above 200 nm.

Filters and/or monochromators may be used in fluorimeters. A monochromator transmits light of an adjustable wavelength with an adjustable tolerance. The most common type of monochromator utilizes a diffraction grating, that is, collimated light illuminates a grating and exits with a different angle depending on the wavelength. The monochromator can then be adjusted to select which wavelengths to transmit. For allowing anisotropy measurements, the addition of two polarization filters is necessary: One after the excitation monochromator or filter, and one before the emission monochromator or filter.

As mentioned before, the fluorescence is most often measured at a 90° angle relative to the excitation light. This geometry is used instead of placing the sensor at the line of the excitation light at a 180° angle in order to avoid interference of the transmitted excitation light. No monochromator is perfect and it will transmit some stray light, that is, light with other wavelengths than the targeted. An ideal monochromator would only transmit light in the specified range and have a high wavelength-independent transmission. When measuring at a 90° angle, only the light scattered by the sample causes stray light. This results in a better signal-to-noise ratio, and lowers the detection limit by approximately a factor 10000,[3] when compared to the 180° geometry. Furthermore, the fluorescence can also be measured from the front, which is often done for turbid or opaque samples .[4]

The detector can either be single-channeled or multichanneled. The single-channeled detector can only detect the intensity of one wavelength at a time, while the multichanneled detects the intensity of all wavelengths simultaneously, making the emission monochromator or filter unnecessary. The different types of detectors have both advantages and disadvantages.

The most versatile fluorimeters with dual monochromators and a continuous excitation light source can record both an excitation spectrum and a fluorescence spectrum. When measuring fluorescence spectra, the wavelength of the excitation light is kept constant, preferably at a wavelength of high absorption, and the emission monochromator scans the spectrum. For measuring excitation spectra, the wavelength passing through the emission filter or monochromator is kept constant and the excitation monochromator is scanning. The excitation spectrum generally is identical to the absorption spectrum as the fluorescence intensity is proportional to the absorption.[5]

Analysis of data[edit]

GNU R export from OpenChrom
OpenFluor plugin in OpenChromshowing substance matchings[6]

At low concentrations the fluorescence intensity will generally be proportional to the concentration of the fluorophore.

Unlike in UV/visible spectroscopy, ‘standard’, device independent spectra are not easily attained. Several factors influence and distort the spectra, and corrections are necessary to attain ‘true’, i.e. machine-independent, spectra. The different types of distortions will here be classified as being either instrument- or sample-related. Firstly, the distortion arising from the instrument is discussed. As a start, the light source intensity and wavelength characteristics varies over time during each experiment and between each experiment. Furthermore, no lamp has a constant intensity at all wavelengths. To correct this, a beam splitter can be applied after the excitation monochromator or filter to direct a portion of the light to a reference detector.

Additionally, the transmission efficiency of monochromators and filters must be taken into account. These may also change over time. The transmission efficiency of the monochromator also varies depending on wavelength. This is the reason that an optional reference detector should be placed after the excitation monochromator or filter. The percentage of the fluorescence picked up by the detector is also dependent upon the system. Furthermore, the detector quantum efficiency, that is, the percentage of photons detected, varies between different detectors, with wavelength and with time, as the detector inevitably deteriorates.

Two other topics that must be considered include the optics used to direct the radiation and the means of holding or containing the sample material (called a cuvette or cell). For most UV, visible, and NIR measurements the use of precision quartz cuvettes is necessary. In both cases, it is important to select materials that have relatively little absorption in the wavelength range of interest. Quartz is ideal because it transmits from 200 nm-2500 nm; higher grade quartz can even transmit up to 3500 nm, whereas the absorption properties of other materials can mask the fluorescence from the sample.

Correction of all these instrumental factors for getting a ‘standard’ spectrum is a tedious process, which is only applied in practice when it is strictly necessary. This is the case when measuring the quantum yield or when finding the wavelength with the highest emission intensity for instance.

As mentioned earlier, distortions arise from the sample as well. Therefore, some aspects of the sample must be taken into account too. Firstly, photodecomposition may decrease the intensity of fluorescence over time. Scattering of light must also be taken into account. The most significant types of scattering in this context are Rayleigh and Raman scattering. Light scattered by Rayleigh scattering has the same wavelength as the incident light, whereas in Raman scattering the scattered light changes wavelength usually to longer wavelengths. Raman scattering is the result of a virtual electronic state induced by the excitation light. From this virtual state, the molecules may relax back to a vibrational level other than the vibrational ground state.[7] In fluorescence spectra, it is always seen at a constant wavenumber difference relative to the excitation wavenumber e.g. the peak appears at a wavenumber 3600 cm−1 lower than the excitation light in water.

Other aspects to consider are the inner filter effects.[8][9] These include reabsorption. Reabsorption happens because another molecule or part of a macromolecule absorbs at the wavelengths at which the fluorophore emits radiation. If this is the case, some or all of the photons emitted by the fluorophore may be absorbed again. Another inner filter effect occurs because of high concentrations of absorbing molecules, including the fluorophore. The result is that the intensity of the excitation light is not constant throughout the solution. Resultingly, only a small percentage of the excitation light reaches the fluorophores that are visible for the detection system. The inner filter effects change the spectrum and intensity of the emitted light and they must therefore be considered when analysing the emission spectrum of fluorescent light.[5][10]

Tryptophan fluorescence[edit]

The fluorescence of a folded protein is a mixture of the fluorescence from individual aromatic residues. Most of the intrinsic fluorescence emissions of a folded protein are due to excitation of tryptophan residues, with some emissions due to tyrosine and phenylalanine; but disulfide bonds also have appreciable absorption in this wavelength range. Typically, tryptophan has a wavelength of maximum absorption of 280 nm and an emission peak that is solvatochromic, ranging from ca. 300 to 350 nm depending in the polarity of the local environment [11] Hence, protein fluorescence may be used as a diagnostic of the conformational state of a protein.[12] Furthermore, tryptophan fluorescence is strongly influenced by the proximity of other residues (i.e., nearby protonated groups such as Asp or Glu can cause quenching of Trp fluorescence). Also, energy transfer between tryptophan and the other fluorescent amino acids is possible, which would affect the analysis, especially in cases where the Förster acidic approach is taken. In addition, tryptophan is a relatively rare amino acid; many proteins contain only one or a few tryptophan residues. Therefore, tryptophan fluorescence can be a very sensitive measurement of the conformational state of individual tryptophan residues. The advantage compared to extrinsic probes is that the protein itself is not changed. The use of intrinsic fluorescence for the study of protein conformation is in practice limited to cases with few (or perhaps only one) tryptophan residues, since each experiences a different local environment, which gives rise to different emission spectra.

Tryptophan is an important intrinsic fluorescent (amino acid), which can be used to estimate the nature of microenvironment of the tryptophan. When performing experiments with denaturants, surfactants or other amphiphilic molecules, the microenvironment of the tryptophan might change. For example, if a protein containing a single tryptophan in its 'hydrophobic' core is denatured with increasing temperature, a red-shifted emission spectrum will appear. This is due to the exposure of the tryptophan to an aqueous environment as opposed to a hydrophobic protein interior. In contrast, the addition of a surfactant to a protein which contains a tryptophan which is exposed to the aqueous solvent will cause a blue-shifted emission spectrum if the tryptophan is embedded in the surfactant vesicle or micelle.[13] Proteins that lack tryptophan may be coupled to a fluorophore.

With fluorescence excitation at 295 nm, the tryptophan emission spectrum is dominant over the weaker tyrosine and phenylalanine fluorescence.

Applications[edit]

Fluorescence spectroscopy is used in, among others, biochemical, medical, and chemical research fields for analyzing organic compounds. There has also been a report of its use in differentiating malignant skin tumors from benign.

Atomic Fluorescence Spectroscopy (AFS) techniques are useful in other kinds of analysis/measurement of a compound present in air or water, or other media, such as CVAFS which is used for heavy metals detection, such as mercury.

Fluorescence can also be used to redirect photons, see fluorescent solar collector.

Additionally, Fluorescence spectroscopy can be adapted to the microscopic level using microfluorimetry

In analytical chemistry, fluorescence detectors are used with HPLC.

In the field of water research, fluorescence spectroscopy can be used to monitor water quality by detecting organic pollutants.[14] Recent advances in computer science and machine learning have even enabled detection of bacterial contamination of water [15]

See also[edit]


https://en.wikipedia.org/wiki/Fluorescence_spectroscopy

09-24-2021-1001 - time signal

A time signal is a visible, audible, mechanical, or electronic signal used as a reference to determine the time of day.

Church bells or voices announcing hours of prayer gave way to automatically operated chimes on public clocks; however, audible signals (even signal guns) have limited range. Busy seaports used a visual signal, the dropping of a ball, to allow mariners to check the chronometers used for navigation. The advent of electrical telegraphsallowed widespread and precise distribution of time signals from central observatories. Railways were among the first customers for time signals, which allowed synchronization of their operations over wide geographic areas. Dedicated radio time signal stations transmit a signal that allows automatic synchronization of clocks, and commercial broadcasters still include time signals in their programming.

Today, global navigation satellite systems (GNSS) radio signals are used to precisely distribute time signals over much of the world. There are many commercially available radio controlled clocks available to accurately indicate the local time, both for business and residential use. Computers often set their time from an Internet atomic clock source. Where this is not available, a locally connected GNSS receiver can precisely set the time using one of several software applications.

These automatic signal clocks were synchronized by telegraphy in 1905 before the widespread use of radio

 https://en.wikipedia.org/wiki/Time_signal



09-24-2021-1000 - Burnt-in timecode BITC VITC

Burnt-in timecode (often abbreviated to BITC by analogy to VITC) is a human-readable on-screen version of the timecode information for a piece of material superimposed on a video image. BITC is sometimes used in conjunction with "real" machine-readable timecode, but more often used in copies of original material on to a non-broadcast format such as VHS, so that the VHS copies can be traced back to their master tape and the original time codes easily located. 

Many professional VTRs can "burn" (overlay) the tape timecode onto one of their outputs. This output (which usually also displays the setup menu or on-screen display) is known as the super out or monitor out. The character switch or menu item turns this behaviour on or off. The character function is also used to display the timecode on the preview monitors in linear editing suites.

Videotapes that are recorded with timecode numbers overlaid on the video are referred to as window dubs, named after the "window" that displays the burnt-in timecode on-screen.

When editing was done using magnetic tapes that were subject to damage from excessive wear, it was common to use a window dub as a working copy for the majority of the editing process. Editing decisions would be made using a window dub, and no specialized equipment was needed to write down an edit decision list which would then be replicated from the high-quality masters.

Timecode can also be superimposed on video using a dedicated overlay device, often called a "window dub inserter". This inputs a video signal and its separate timecode audio signal, reads the timecode, superimposes the timecode display over the video, and outputs the combined display (usually via composite), all in real time. Stand-alone timecode generator / readers often have the window dub function built-in. 

Some consumer cameras, in particular DV cameras, can "burn" (overlay) the tape timecode onto the composite output. This output typically is semi-transparent and may include other tape information. It is usually activated by turning on the 'display' info in one of the camera's sub-menus. While not as 'professional' as an overlay as created by a professional VCRs, it is a cheap alternative that is just as accurate.

Timecode is stored in the metadata areas of captured DV AVI files, and some software is able to "burn" (overlay) this into the video frames. For example, DVMP Pro[1] is able to "burn" timecode or other items of DV metadata (such as date and time, iris, shutter speed, gain, white balance mode, etc.) into DV AVI files.

Color bars with burnt-in timecode

See also[edit]

Categories: 

https://en.wikipedia.org/wiki/Burnt-in_timecode





09-24-2021-0938 - Grapheme–color synaesthesia or colored grapheme synesthesia

 Grapheme–color synaesthesia or colored grapheme synesthesia is a form of synesthesia in which an individual's perception of numerals and letters is associated with the experience of colors. Like all forms of synesthesia, grapheme–color synesthesia is involuntary, consistent and memorable.[1][failed verification]Grapheme–color synesthesia is one of the most common forms of synesthesia and, because of the extensive knowledge of the visual system, one of the most studied.[2]

While it is extremely unlikely that any two synesthetes will report the same colors for all letters and numbers, studies of large numbers of synesthetes find that there are some commonalities across letters (e.g., "A" is likely to be red).[3][4] Early studies argued that grapheme–color synesthesia was not due to associative learning, such as from playing with colored refrigerator magnets.[5] However, one recent study has documented a case of synesthesia in which synesthetic associations could be traced back to colored refrigerator magnets.[6]Despite the existence of this individual case, the majority of synesthetic associations do not seem to be driven by learning of this sort.[4][7] Rather, it seems that more frequent letters are paired with more frequent colors, and some meaning-based rules, such as ‘b’ being blue, drive most synesthetic associations.

There has been a lot more research as to why and how synesthesia occurs with more recent technology and as synesthesia has become more well known. It has been found that grapheme–color synesthetes have more grey matter in their brain. There is evidence of an increased grey matter volume in the left caudal intraparietal sulcus (IPS).[8] There was also found to be an increased grey matter volume in the right fusiform gyrus. These results are consistent with another study on the brain functioning of grapheme–color synesthetes. Grapheme–color synesthetes tend to have an increased thickness, volume and surface area of the fusiform gyrus.[2] Furthermore, the area of the brain where word, letter and color processing are located, V4a, is where the most significant difference in make-up was found. Though not certain, these differences are thought to be part of the reasoning for the presence of grapheme–color synesthesia.

How someone with grapheme–color synesthesia might perceive (not "see") certain letters and numbers

https://en.wikipedia.org/wiki/Grapheme–color_synesthesia


https://en.wikipedia.org/wiki/Dihedral_angle

https://en.wikipedia.org/wiki/Digital_object_identifier

https://en.wikipedia.org/wiki/String_instrument

https://en.wikipedia.org/wiki/Harmonic

https://en.wikipedia.org/wiki/Fundamental_frequency

https://en.wikipedia.org/wiki/Zeron_100

https://en.wikipedia.org/wiki/Zero_crossing

https://en.wikipedia.org/wiki/Relay

https://en.wikipedia.org/wiki/Rate_of_change

https://en.wikipedia.org/wiki/Electrical_contacts#Contact_form

https://en.wikipedia.org/wiki/Switch#Break-before-make

https://en.wikipedia.org/wiki/Relay#Mercury-wetted_relay

https://en.wikipedia.org/wiki/Overcurrent

https://en.wikipedia.org/wiki/Electrical_fault

https://en.wikipedia.org/wiki/Conductor_clashing

https://en.wikipedia.org/wiki/Utility_pole

https://en.wikipedia.org/wiki/Telegraphy

https://en.wikipedia.org/wiki/genetic_modification

https://en.wikipedia.org/wiki/genetic

https://en.wikipedia.org/wiki/error_correction

https://en.wikipedia.org/wiki/convergence

https://en.wikipedia.org/wiki/splitting

https://en.wikipedia.org/wiki/quantum_computing

https://en.wikipedia.org/wiki/ion

https://en.wikipedia.org/wiki/rate

https://en.wikipedia.org/wiki/coupling

https://en.wikipedia.org/wiki/signal_amplification

https://en.wikipedia.org/wiki/emissions_spectra

https://en.wikipedia.org/wiki/simultaneous_signal

https://en.wikipedia.org/wiki/jamming_(physics)

https://en.wikipedia.org/wiki/quadpole

https://en.wikipedia.org/wiki/mirror

https://en.wikipedia.org/wiki/inversion

https://en.wikipedia.org/wiki/Optical_telegraph


https://en.wikipedia.org/wiki/Nonimaging_optics

https://en.wikipedia.org/wiki/Optical_fiber

https://en.wikipedia.org/wiki/Dispersion_(optics)

https://en.wikipedia.org/wiki/X-ray_optics

https://en.wikipedia.org/wiki/Ammonium_dihydrogen_phosphate

https://en.wikipedia.org/wiki/Exit_pupil

https://en.wikipedia.org/wiki/Dispersive_prism

https://en.wikipedia.org/wiki/Caustic_(optics)


https://en.wikipedia.org/w/index.php?search=compounding+optics&title=Special:Search&go=Go&ns0=1&searchToken=3wiqjo0c839mr3m48dxvyi3dw

https://en.wikipedia.org/wiki/drugs

https://en.wikipedia.org/wiki/toxin

https://en.wikipedia.org/wiki/metabolite

https://en.wikipedia.org/wiki/metabolic_byproduct

https://en.wikipedia.org/wiki/agglomeration

https://en.wikipedia.org/wiki/accumulation

https://en.wikipedia.org/wiki/warp

https://en.wikipedia.org/wiki/radioactivity

https://en.wikipedia.org/wiki/barium

https://en.wikipedia.org/wiki/boron

https://en.wikipedia.org/wiki/nitrogen

https://en.wikipedia.org/wiki/stereochemistry

https://en.wikipedia.org/wiki/genetics

https://en.wikipedia.org/wiki/biology

https://en.wikipedia.org/wiki/human_anatomy

https://en.wikipedia.org/wiki/human_physiology

https://en.wikipedia.org/wiki/animal_physiology

https://en.wikipedia.org/wiki/gene

https://en.wikipedia.org/wiki/protein

https://en.wikipedia.org/wiki/supramolecular_chemistry

https://en.wikipedia.org/wiki/tertiary

https://en.wikipedia.org/wiki/polymer

https://en.wikipedia.org/wiki/protein

https://en.wikipedia.org/wiki/prion

https://en.wikipedia.org/wiki/interference

https://en.wikipedia.org/wiki/cascade

https://en.wikipedia.org/wiki/chain

https://en.wikipedia.org/wiki/chunking_(psychology)


https://en.wikipedia.org/wiki/Solid-state_relay

https://en.wikipedia.org/wiki/Thyristor

https://en.wikipedia.org/wiki/Avalanche_breakdown

https://en.wikipedia.org/wiki/Electron_avalanche

https://en.wikipedia.org/wiki/Photoelectric_effect

https://en.wikipedia.org/wiki/thermionic_emission


https://en.wikipedia.org/wiki/Vectrex#Screen_overlays

https://en.wikipedia.org/wiki/SCART#RGB_overlays

https://en.wikipedia.org/wiki/Radio_navigation

https://en.wikipedia.org/wiki/Track_Warrant_Control

https://en.wikipedia.org/wiki/Jungle_chip

https://en.wikipedia.org/wiki/Real-time_kinematic_positioning

https://en.wikipedia.org/wiki/European_Geostationary_Navigation_Overlay_Service

https://en.wikipedia.org/wiki/Augmented_reality


https://en.wikipedia.org/wiki/Burnt-in_timecode


https://en.wikipedia.org/wiki/Time_signal


https://en.wikipedia.org/wiki/Signal_transduction

https://en.wikipedia.org/wiki/absorption

https://en.wikipedia.org/wiki/reflection

https://en.wikipedia.org/wiki/rarefaction

https://en.wikipedia.org/wiki/osculation

https://en.wikipedia.org/wiki/collision

https://en.wikipedia.org/wiki/magnet

https://en.wikipedia.org/wiki/decoupling_optics


https://en.wikipedia.org/wiki/Signal_peptide

https://en.wikipedia.org/wiki/Cell_signaling

https://en.wikipedia.org/wiki/Open_reading_frame#Six-frame_translation

https://en.wikipedia.org/wiki/Level_shifter

https://en.wikipedia.org/wiki/Signaling_gateway

https://en.wikipedia.org/wiki/Translation_lookaside_buffer

https://en.wikipedia.org/wiki/Virtual_memory

https://en.wikipedia.org/wiki/Game_theory

https://en.wikipedia.org/wiki/Probability

https://en.wikipedia.org/wiki/Complex_system


https://en.wikipedia.org/wiki/Fidelity

https://en.wikipedia.org/wiki/Protein_targeting

https://en.wikipedia.org/wiki/Composite_video

https://en.wikipedia.org/wiki/Time_signal

https://en.wikipedia.org/wiki/Complex_system


https://en.wikipedia.org/wiki/Sigaction

https://en.wikipedia.org/wiki/Apodization

https://en.wikipedia.org/wiki/Secretory_protein

https://en.wikipedia.org/wiki/Signal_recognition_particle_RNA

https://en.wikipedia.org/wiki/Transcription-translation_coupling

https://en.wikipedia.org/wiki/Stream_Control_Transmission_Protocol

https://en.wikipedia.org/wiki/Nuclear_localization_sequence

https://en.wikipedia.org/wiki/DNA_and_RNA_codon_tables#Translation_table_1

https://en.wikipedia.org/wiki/Gene_prediction#Other_signals

https://en.wikipedia.org/wiki/Artificial_neural_network


https://en.wikipedia.org/wiki/Artificial_neural_network

https://en.wikipedia.org/wiki/Fluorescence_spectroscopy



09-24-2021-0936 - viability assay

A viability assay is an assay that is created to determine the ability of organs, cells or tissues to maintain or recover a state of survival. Viability can be distinguished from the all-or-nothing states of life and death by the use of a quantifiable index that ranges between the integers of 0 and 1 or, if more easily understood, the range of 0% and 100%.[2] Viability can be observed through the physical properties of cells, tissues, and organs. Some of these include mechanical activity, motility, such as with spermatozoa and granulocytes, the contraction of muscle tissue or cells, mitotic activity in cellular functions, and more.[2] Viability assays provide a more precise basis for measurement of an organism's level of vitality.

Viability assays can lead to more findings than the difference of living versus nonliving. These techniques can be used to assess the success of cell culture techniques, cryopreservation techniques, the toxicity of substances, or the effectiveness of substances in mitigating effects of toxic substances.[3]

This plated viability assay measures various yeast viability though a method called "frogging". The research is completed through drop-inoculation techniques. Research has since been conducted on "tadpoling", which is a variation of "frogging" that is completed by keeping the test cells diluted in liquid throughout their examination.[1]

https://en.wikipedia.org/wiki/Viability_assay

09-24-2021-0935 - Phloxine B

 Phloxine B (commonly known simply as phloxine) is a water-soluble red dye used for coloring drugs and cosmetics in the United States[2] and coloring food in Japan.[3] It is derived from fluorescein, but differs by the presence of four bromine atoms at positions 2, 4, 5 and 7 of the xanthene ring and four chlorine atoms in the carboxyphenyl ring.[4] It has an absorption maximum around 540 nm and an emission maximum around 564 nm.[5] Apart from industrial use, phloxine B has functions as an antimicrobial substance, viability dye and biological stain.[6] For example, it is used in hematoxylin-phloxine-saffron (HPS) staining to color the cytoplasmand connective tissue in shades of red.[7]

Phloxine.png

https://en.wikipedia.org/wiki/Phloxine

09-24-2021-0908 - Wonders of Chemistry & The Wonder World of Chemistry 1936 DuPont; Chemical Industry Classic Film

The Wonder World of Chemistry 1936 DuPont; Chemical Industry Classic Film

https://vimeo.com/328077259


Wonders of chemistry

https://archive.org/details/wonderschemistr00collgoog


09-24-2021-0907 - Science History Institute

Science History Institute

 

https://digital.sciencehistory.org/works/3xa4x78