Neutron generators are neutron source devices which contain compact linear particle accelerators and that produce neutrons by fusing isotopes of hydrogen together. The fusion reactions take place in these devices by accelerating either deuterium, tritium, or a mixture of these two isotopes into a metal hydride target which also contains deuterium, tritium or a mixture of these isotopes. Fusion of deuterium atoms (D + D) results in the formation of a He-3 ion and a neutron with a kinetic energy of approximately 2.5 MeV. Fusion of a deuterium and a tritium atom (D + T) results in the formation of a He-4 ion and a neutron with a kinetic energy of approximately 14.1 MeV. Neutron generators have applications in medicine, security, and materials analysis.[1]
The basic concept was first developed by Ernest Rutherford's team in the Cavendish Laboratory in the early 1930s. Using a linear accelerator driven by a Cockcroft–Walton generator, Mark Oliphant led an experiment that fired deuterium ions into a deuterium-infused metal foil and noticed that a small number of these particles gave off alpha particles. This was the first demonstration of nuclear fusion, as well as the first discovery of Helium-3 and tritium, created in these reactions. The introduction of new power sources has continually shrunk the size of these machines, from Oliphant's that filled the corner of the lab, to modern machines that are highly portable. Thousands of such small, relatively inexpensive systems have been built over the past five decades.
While neutron generators do produce fusion reactions, the number of accelerated ions that cause these reactions is very low. It can be easily demonstrated that the energy released by these reactions is many times lower than the energy needed to accelerate the ions, so there is no possibility of these machines being used to produce net fusion power. A related concept, colliding beam fusion, attempts to address this issue using two accelerators firing at each other.
Sealed neutron tubes[edit]
The central part of a neutron generator is the particle accelerator itself, sometimes called a neutron tube. Neutron tubes have several components including an ion source, ion optic elements, and a beam target; all of these are enclosed within a vacuum-tight enclosure. High voltage insulation between the ion optical elements of the tube is provided by glass and/or ceramic insulators. The neutron tube is, in turn, enclosed in a metal housing, the accelerator head, which is filled with a dielectric medium to insulate the high voltage elements of the tube from the operating area. The accelerator and ion source high voltages are provided by external power supplies. The control console allows the operator to adjust the operating parameters of the neutron tube. The power supplies and control equipment are normally located within 10–30 feet of the accelerator head in laboratory instruments, but may be several kilometers away in well logging instruments.
In comparison with their predecessors, sealed neutron tubes do not require vacuum pumps and gas sources for operation. They are therefore more mobile and compact, while also durable and reliable. For example, sealed neutron tubes have replaced radioactive modulated neutron initiators, in supplying a pulse of neutrons to the imploding core of modern nuclear weapons.
Examples of neutron tube ideas date as far back as the 1930s, pre-nuclear weapons era, by German scientists filing a 1938 German patent (March 1938, patent # 261,156) and obtaining a United States Patent (July 1941, USP#2,251,190); examples of present state of the art are given by developments such as the Neutristor,[3] a mostly solid state device, resembling a computer chip, invented at Sandia National Laboratories in Albuquerque NM.[citation needed] Typical sealed designs are used in a pulsed mode[4] and can be operated at different output levels, depending on the life from the ion source and loaded targets.[5]
Ion sources[edit]
A good ion source should provide a strong ion beam without consuming much of the gas. For hydrogen isotopes, production of atomic ions is favored over molecular ions, as atomic ions have higher neutron yield on collision. The ions generated in the ion source are then extracted by an electric field into the accelerator region, and accelerated towards the target. The gas consumption is chiefly caused by the pressure difference between the ion generating and ion accelerating spaces that has to be maintained. Ion currents of 10 mA at gas consumptions of 40 cm3/hour are achievable.[2]
For a sealed neutron tube, the ideal ion source should use low gas pressure, give high ion current with large proportion of atomic ions, have low gas clean-up, use low power, have high reliability and high lifetime, its construction has to be simple and robust and its maintenance requirements have to be low.[2]
Gas can be efficiently stored in a replenisher, an electrically heated coil of zirconium wire. Its temperature determines the rate of absorption/desorption of hydrogen by the metal, which regulates the pressure in the enclosure.
Radio frequency (RF)[edit]
Ions can be created by electrons formed in high-frequency electromagnetic field. The discharge is formed in a tube located between electrodes, or inside a coil. Over 90% proportion of atomic ions is achievable.[2]
Targets[edit]
The targets used in neutron generators are thin films of metal such as titanium, scandium, or zirconium which are deposited onto a silver, copper or molybdenum substrate. Titanium, scandium, and zirconium form stable chemical compounds called metal hydrides when combined with hydrogen or its isotopes. These metal hydrides are made up of two hydrogen (deuterium or tritium) atoms per metal atom and allow the target to have extremely high densities of hydrogen. This is important to maximize the neutron yield of the neutron tube. The gas reservoir element also uses metal hydrides, e.g. uranium hydride, as the active material.
Titanium is preferred to zirconium as it can withstand higher temperatures (200 °C), and gives higher neutron yield as it captures deuterons better than zirconium. The maximum temperature allowed for the target, above which hydrogen isotopes undergo desorption and escape the material, limits the ion current per surface unit of the target; slightly divergent beams are therefore used. A 1 microampere ion beam accelerated at 200 kV to a titanium-tritium target can generate up to 108 neutrons per second. The neutron yield is mostly determined by the accelerating voltage and the ion current level.[2]
An example of a tritium target in use is a 0.2 mm thick silver disc with a 1 micrometer layer of titanium deposited on its surface; the titanium is then saturated with tritium.[2]
Metals with sufficiently low hydrogen diffusion can be turned into deuterium targets by bombardment of deuterons until the metal is saturated. Gold targets under such condition show four times higher efficiency than titanium. Even better results can be achieved with targets made of a thin film of a high-absorption high-diffusivity metal (e.g. titanium) on a substrate with low hydrogen diffusivity (e.g. silver), as the hydrogen is then concentrated on the top layer and can not diffuse away into the bulk of the material. Using a deuterium-tritium gas mixture, self-replenishing D-T targets can be made. The neutron yield of such targets is lower than of tritium-saturated targets in deuteron beams, but their advantage is much longer lifetime and constant level of neutron production. Self-replenishing targets are also tolerant to high-temperature bake-out of the tubes, as their saturation with hydrogen isotopes is performed after the bakeout and tube sealing.[2]
High voltage power supplies[edit]
One particularly interesting approach for generating the high voltage fields needed to accelerate ions in a neutron tube is to use a pyroelectric crystal. In April 2005 researchers at UCLA demonstrated the use of a thermally cycled pyroelectric crystal to generate high electric fields in a neutron generator application. In February 2006 researchers at Rensselaer Polytechnic Institute demonstrated the use of two oppositely poled crystals for this application. Using these low-tech power supplies it is possible to generate a sufficiently high electric field gradient across an accelerating gap to accelerate deuterium ions into a deuterated target to produce the D + D fusion reaction. These devices are similar in their operating principle to conventional sealed-tube neutron generators which typically use Cockcroft–Walton type high voltage power supplies. The novelty of this approach is in the simplicity of the high voltage source. Unfortunately, the relatively low accelerating current that pyroelectric crystals can generate, together with the modest pulsing frequencies that can be achieved (a few cycles per minute) limits their near-term application in comparison with today's commercial products (see below). Also see pyroelectric fusion.[6]
Other technologies[edit]
In addition to the conventional neutron generator design described above several other approaches exist to use electrical systems for producing neutrons.
Inertial electrostatic confinement/fusor[edit]
Another type of innovative neutron generator is the inertial electrostatic confinement fusion device. This neutron generator avoids using a solid target which will be sputter eroded causing metalization of insulating surfaces. Depletion of the reactant gas within the solid target is also avoided. Far greater operational lifetime is achieved. Originally called a fusor, it was invented by Philo Farnsworth, the inventor of electronic television.
See also[edit]
- Fast neutron
- Nuclear fission
- Nuclear fusion
- Neutron source
- Neutron moderator
- Radioactive decay
- Slow neutron
- Zetatron
https://en.wikipedia.org/wiki/Neutron_generator
No comments:
Post a Comment