A synchrotron light source is a source of electromagnetic radiation (EM) usually produced by a storage ring,[1] for scientific and technical purposes. First observed in synchrotrons, synchrotron light is now produced by storage rings and other specialized particle accelerators, typically accelerating electrons. Once the high-energy electron beam has been generated, it is directed into auxiliary components such as bending magnets and insertion devices (undulators or wigglers) in storage rings and free electron lasers. These supply the strong magnetic fields perpendicular to the beam which are needed to convert high energy electrons into photons.
The major applications of synchrotron light are in condensed matter physics, materials science, biology and medicine. A large fraction of experiments using synchrotron light involve probing the structure of matter from the sub-nanometer level of electronic structure to the micrometer and millimeter level important in medical imaging. An example of a practical industrial application is the manufacturing of microstructures by the LIGA process.
Brilliance[edit]
When comparing x-ray sources, an important measure of quality of the source is called brilliance.[2] Brilliance takes into account:
- Number of photons produced per second
- The angular divergence of the photons, or how fast the beam spreads out
- The cross-sectional area of the beam
- The photons falling within a bandwidth (BW) of 0.1% of the central wavelength or frequency
The resulting formula is:
The greater the brilliance, the more photons of a given wavelength and direction are concentrated on a spot per unit of time.
Especially when artificially produced, synchrotron radiation is notable for its:
- High brilliance, many orders of magnitude more than with X-rays produced in conventional X-ray tubes: 3rd generation sources typically have a brilliance larger than 1018 photons·s−1·mm−2·mrad−2/0.1%BW, where 0.1%BW denotes a bandwidth 10−3w centered around the frequency w.
- High level of polarization (linear, elliptical or circular)
- High collimation, i.e. small angular divergence of the beam
- Low emittance, i.e. the product of source cross section and solid angle of emission is small
- Wide tunability in energy/wavelength by monochromatization (sub-electronvolt up to the megaelectronvolt range)
- Pulsed light emission (pulse durations at or below one nanosecond, or a billionth of a second).
The advantages of using synchrotron radiation for spectroscopy and diffraction have been realized by an ever-growing scientific community, beginning in the 1960s and 1970s. In the beginning, accelerators were built for particle physics, and synchrotron radiation was used in "parasitic mode" when bending magnet radiation had to be extracted by drilling extra holes in the beam pipes. The first storage ring commissioned as a synchrotron light source was Tantalus, at the Synchrotron Radiation Center, first operational in 1968.[3] As accelerator synchrotron radiation became more intense and its applications more promising, devices that enhanced the intensity of synchrotron radiation were built into existing rings. Third-generation synchrotron radiation sources were conceived and optimized from the outset to produce brilliant X-rays. Fourth-generation sources that will include different concepts for producing ultrabrilliant, pulsed time-structured X-rays for extremely demanding and also probably yet-to-be-conceived experiments are under consideration.[citation needed]
Bending electromagnets in accelerators were first used to generate this radiation, but to generate stronger radiation, other specialized devices – insertion devices – are sometimes employed. Current (third-generation) synchrotron radiation sources are typically reliant upon these insertion devices, where straight sections of the storage ring incorporate periodic magnetic structures (comprising many magnets in a pattern of alternating N and S poles – see diagram above) which force the electrons into a sinusoidal or helical path. Thus, instead of a single bend, many tens or hundreds of "wiggles" at precisely calculated positions add up or multiply the total intensity of the beam.[citation needed]
These devices are called wigglers or undulators. The main difference between an undulator and a wiggler is the intensity of their magnetic field and the amplitude of the deviation from the straight line path of the electrons.[citation needed]
There are openings in the storage ring to let the radiation exit and follow a beam line into the experimenters' vacuum chamber. A great number of such beamlines can emerge from modern third-generation synchrotron radiation sources.[citation needed]
The electrons may be extracted from the accelerator proper and stored in an ultrahigh vacuum auxiliary magnetic storage ring where they may circle a large number of times. The magnets in the ring also need to repeatedly recompress the beam against Coulomb (space charge) forces tending to disrupt the electron bunches. The change of direction is a form of acceleration and thus the electrons emit radiation at GeV energies.[citation needed]
- Synchrotron radiation of an electron beam circulating at high energy in a magnetic field leads to radiative self-polarization of electrons in the beam (Sokolov–Ternov effect).[4] This effect is used for producing highly polarised electron beams for use in various experiments.[citation needed]
- Synchrotron radiation sets the beam sizes (determined by the beam emittance) in electron storage rings via the effects of radiation damping and quantum excitation.[5]
The beamline includes X-ray optical devices which control the bandwidth, photon flux, beam dimensions, focus, and collimation of the rays. The optical devices include slits, attenuators, crystal monochromators, and mirrors. The mirrors may be bent into curves or toroidal shapes to focus the beam. A high photon flux in a small area is the most common requirement of a beamline. The design of the beamline will vary with the application. At the end of the beamline is the experimental end station, where samples are placed in the line of the radiation, and detectors are positioned to measure the resulting diffraction, scattering or secondary radiation.
Diffraction and scattering[edit]
X-ray diffraction (XRD) and scattering experiments are performed at synchrotrons for the structural analysis of crystalline and amorphous materials. These measurements may be performed on powders, single crystals, or thin films. The high resolution and intensity of the synchrotron beam enables the measurement of scattering from dilute phases or the analysis of residual stress. Materials can be studied at high pressure using diamond anvil cells to simulate extreme geologic environments or to create exotic forms of matter.[citation needed]
X-ray crystallography of proteins and other macromolecules (PX or MX) are routinely performed. Synchrotron-based crystallography experiments were integral to solving the structure of the ribosome;[7][8] this work earned the Nobel Prize in Chemistry in 2009.
The size and shape of nanoparticles are characterized using small angle X-ray scattering (SAXS). Nano-sized features on surfaces are measured with a similar technique, grazing-incidence small angle X-ray scattering(GISAXS).[9] In this and other methods, surface sensitivity is achieved by placing the crystal surface at a small angle relative to the incident beam, which achieves total external reflection and minimizes the X-ray penetration into the material.[citation needed]
The atomic- to nano-scale details of surfaces, interfaces, and thin films can be characterized using techniques such as X-ray reflectivity (XRR) and crystal truncation rod (CTR) analysis.[10] X-ray standing wave (XSW) measurements can also be used to measure the position of atoms at or near surfaces; these measurements require high-resolution optics capable of resolving dynamical diffraction phenomena.[11]
Amorphous materials, including liquids and melts, as well as crystalline materials with local disorder, can be examined using X-ray pair distribution function analysis, which requires high energy X-ray scattering data.[12]
By tuning the beam energy through the absorption edge of a particular element of interest, the scattering from atoms of that element will be modified. These so-called resonant anomalous X-ray scattering methods can help to resolve scattering contributions from specific elements in the sample.[citation needed]
Other scattering techniques include energy dispersive X-ray diffraction, resonant inelastic X-ray scattering, and magnetic scattering.[citation needed]
Spectroscopy[edit]
X-ray absorption spectroscopy (XAS) is used to study the coordination structure of atoms in materials and molecules. The synchrotron beam energy is tuned through the absorption edge of an element of interest, and modulations in the absorption are measured. Photoelectron transitions cause modulations near the absorption edge, and analysis of these modulations (called the X-ray absorption near-edge structure (XANES) or near-edge X-ray absorption fine structure (NEXAFS)) reveals information about the chemical state and local symmetry of that element. At incident beam energies which are much higher than the absorption edge, photoelectron scattering causes "ringing" modulations called the extended X-ray absorption fine structure(EXAFS). Fourier transformation of the EXAFS regime yields the bond lengths and number of the surrounding the absorbing atom; it is therefore useful for studying liquids and amorphous materials[13] as well as sparse species such as impurities. A related technique, X-ray magnetic circular dichroism(XMCD), uses circularly polarized X-rays to measure the magnetic properties of an element.[citation needed]
X-ray photoelectron spectroscopy (XPS) can be performed at beamlines equipped with a photoelectron analyzer. Traditional XPS is typically limited to probing the top few nanometers of a material under vacuum. However, the high intensity of synchrotron light enables XPS measurements of surfaces at near-ambient pressures of gas. Ambient pressure XPS (AP-XPS) can be used to measure chemical phenomena under simulated catalytic or liquid conditions.[14] Using high-energy photons yields high kinetic energy photoelectrons which have a much longer inelastic mean free path than those generated on a laboratory XPS instrument. The probing depth of synchrotron XPS can therefore be lengthened to several nanometers, allowing the study of buried interfaces. This method is referred to as high-energy X-ray photoemission spectroscopy (HAXPES).[15]
Material composition can be quantitatively analyzed using X-ray fluorescence (XRF). XRF detection is also used in several other techniques, such as XAS and XSW, in which it is necessary to measure the change in absorption of a particular element.[citation needed]
Other spectroscopy techniques include angle resolved photoemission spectroscopy (ARPES), soft X-ray emission spectroscopy, and nuclear resonance vibrational spectroscopy, which is related to Mössbauer spectroscopy.[citation needed]
Imaging[edit]
Synchrotron X-rays can be used for traditional X-ray imaging, phase-contrast X-ray imaging, and tomography. The Ångström-scale wavelength of X-rays enables imaging well below the diffraction limit of visible light, but practically the smallest resolution so far achieved is about 30 nm.[16] Such nanoprobe sources are used for scanning transmission X-ray microscopy (STXM). Imaging can be combined with spectroscopy such as X-ray fluorescence or X-ray absorption spectroscopy in order to map a sample's chemical composition or oxidation state with sub-micron resolution.[17]
Other imaging techniques include coherent diffraction imaging.[citation needed]
Similar optics can be employed for photolithography for MEMS structures can use a synchrotron beam as part of the LIGA process.[citation needed]
Compact synchrotron light sources[edit]
Because of the usefulness of tuneable collimated coherent X-ray radiation, efforts have been made to make smaller more economical sources of the light produced by synchrotrons. The aim is to make such sources available within a research laboratory for cost and convenience reasons; at present, researchers have to travel to a facility to perform experiments. One method of making a compact light source is to use the energy shift from Compton scattering near-visible laser photons from electrons stored at relatively low energies of tens of megaelectronvolts (see for example the Compact Light Source (CLS)[18]). However, a relatively low cross-section of collision can be obtained in this manner, and the repetition rate of the lasers is limited to a few hertz rather than the megahertz repetition rates naturally arising in normal storage ring emission. Another method is to use plasma acceleration to reduce the distance required to accelerate electrons from rest to the energies required for UV or X-ray emission within magnetic devices.[citation needed]
See also[edit]
https://en.wikipedia.org/wiki/Synchrotron_light_source
In radiometry, radiance is the radiant flux emitted, reflected, transmitted or received by a given surface, per unit solid angle per unit projected area. Spectral radiance is the radiance of a surface per unit frequency or wavelength, depending on whether the spectrum is taken as a function of frequency or of wavelength. These are directional quantities. The SI unit of radiance is the watt per steradian per square metre (W·sr−1·m−2), while that of spectral radiance in frequency is the watt per steradian per square metre per hertz (W·sr−1·m−2·Hz−1) and that of spectral radiance in wavelength is the watt per steradian per square metre per metre (W·sr−1·m−3)—commonly the watt per steradian per square metre per nanometre (W·sr−1·m−2·nm−1). The microflick is also used to measure spectral radiance in some fields.[1][2] Radiance is used to characterize diffuse emission and reflection of electromagnetic radiation, or to quantify emission of neutrinos and other particles. Historically, radiance is called "intensity" and spectral radiance is called "specific intensity". Many fields still use this nomenclature. It is especially dominant in heat transfer, astrophysics and astronomy. "Intensity" has many other meanings in physics, with the most common being power per unit area.
https://en.wikipedia.org/wiki/Radiance
https://resources.perkinelmer.com/lab-solutions/resources/docs/TCH_DNA_radionucleotides_table.pdf
https://www.ncbi.nlm.nih.gov/labs/virus/vssi/#/virus?SeqType_s=Nucleotide&VirusLineage_ss=SARS-CoV-2,%20taxid:2697049
No comments:
Post a Comment